
Docs · Place
Buildings
A building buys power, heat and water and is judged on carbon. The owner pays for the work, the tenant gets the lower bill, and the city sets the fine.
Where the systems meet
Cooling plant and towers
EnergyWaterCarbon
A cooling tower evaporates water to reject heat. Less load is less power, less water and fewer emissions.
Heat pumps and electrification
EnergyCarbon
Gas use ends and the electric bill rises. Whether carbon falls depends on the grid, hour by hour.
Envelope and controls retrofit
EnergyCarbon
Often the cheapest tonnes in a building. Where a performance standard applies, the avoided fine is part of the return.
Leak detection and water reuse
WaterEnergy
Less water bought and less sewer charge. Hot water saved is also energy saved.
Rooftop solar and storage
EnergyCarbon
Lower bills and demand charges. Who holds the certificates decides who may claim the power is clean.
Data centre cooling
EnergyWaterCarbon
Evaporative cooling saves power and spends water. Dry cooling does the reverse. The right answer depends on the basin and the grid.
Low-carbon materials
Carbon
Concrete and steel are most of the emissions of a new building before it opens. Buyers increasingly ask for the footprint per unit.
Reading 61
61 of 61
- Standard
BREEAM
BRE
The rating system most used in the UK and Europe.
EnergyWaterCarbon
- Standard
Corporate Accounting and Reporting Standard
GHG Protocol
The base rules for a company emissions inventory. Scopes 1, 2 and 3 are defined here.
Carbon
- Standard
Corporate Net-Zero Standard
Science Based Targets initiative
What a corporate buyer has committed to, and so what it will pay a supplier for.
Carbon
- Standard
Corporate Value Chain (Scope 3) Standard
GHG Protocol
Why your customer cares about your emissions: your Scope 1 is their Scope 3.
Carbon
- Standard
Granular Certificate Scheme Standard
EnergyTag
Hourly certificates. Where clean-power claims are heading.
Energy
- Standard
Green-e certification
Center for Resource Solutions
The US consumer-protection standard for renewable energy and certificate sales.
Energy
- Standard
IFRS S2: climate-related disclosures
International Sustainability Standards Board
The global baseline for climate disclosure. What your customers and lenders will report.
Carbon
- Standard
International Water Stewardship Standard
Alliance for Water Stewardship
Site-level certification. Asked for by buyers in food, beverage and electronics.
Water
- Standard
ISO 46001: water efficiency management systems
ISO
A management system for water use, built like ISO 50001 for energy.
Water
- Standard
ISO 50001: energy management
ISO
The management system for energy performance.
Energy
- Standard
LEED
US Green Building Council
The most widely used green building rating. Often written into leases and loan terms.
EnergyWaterCarbon
- Standard
MLPerf benchmarks
MLCommons
Published results for the same workloads across different systems. The closest thing compute has to a common measure of work done.
Compute
- Standard
NABERS UK
NABERS UK
Rates offices on measured energy use in operation, not on design intent.
Energy
- Standard
Open Compute Project
Open Compute Project Foundation
Open hardware specifications for servers, racks and cooling. How data centre equipment is described and built to a shared design.
ComputeEnergy
- Standard
RE100 technical criteria
Climate Group and CDP
What counts as renewable electricity for the largest corporate buyers.
Energy
- Standard
Scope 2 Guidance
GHG Protocol
How purchased electricity is counted. Decides what a certificate or a power contract is worth to its buyer.
EnergyCarbon
- Standard
Software Carbon Intensity specification
Green Software Foundation
A method for stating the carbon emitted per unit of software work, such as per user or per request.
ComputeCarbon
- Standard
SPEC benchmarks
Standard Performance Evaluation Corporation
Long-running industry benchmarks for servers, including performance per unit of power.
ComputeEnergy
- Standard
The Green Grid
The Green Grid
Source of the data centre measures for power and water use (PUE and WUE).
EnergyWaterCompute
- Standard
Volumetric Water Benefit Accounting (VWBA) 2.0
World Resources Institute
The method for counting the volume a water project delivers. What a replenishment buyer will ask for.
Water
- Standard
WaterSense
US EPA
Efficiency specifications for fixtures and irrigation controllers, and commercial best practices.
Water
- Regulation
Corporate sustainability reporting
European Commission
EU reporting rules that reach suppliers through their customers.
CarbonWaterEnergy
- Regulation
Energy Performance of Buildings Directive
European Commission
The EU rules for new and existing buildings, including minimum performance for the worst of the stock.
EnergyCarbon
- Regulation
Energy performance of data centres
European Commission
EU rules requiring data centres to report energy and water use, and the planned rating scheme.
ComputeEnergyWater
- Regulation
Green Guides
US Federal Trade Commission
US rules on environmental marketing claims, including renewable energy and offset claims.
CarbonEnergyWater
- Regulation
Local Law 97
New York City Department of Buildings
Emission limits for large buildings with a fine per tonne over the limit. The clearest case of carbon as a line on a building's budget.
CarbonEnergy
- Regulation
Stationary refrigeration and air conditioning (Section 608)
US EPA
US rules on refrigerant leaks and handling. Refrigerants are a large and often uncounted part of a building's emissions.
Carbon
- Registry
I-REC and the International Attribute Tracking Standard
I-TRACK Foundation
Energy certificates in countries without a national system.
Energy
- Incentive
Energy efficient commercial buildings deduction (179D)
US Internal Revenue Service
A US tax deduction per square foot for efficient commercial buildings. Changed by law in 2025; check what still applies.
Energy
- Guidance
Best Management Practice 10: Cooling Tower Management
US Department of Energy
How a cooling tower uses water and where the savings are. The plainest account of water and energy in one machine.
WaterEnergy
- Guidance
Carbon Leadership Forum
Carbon Leadership Forum
Benchmarks and methods for the emissions built into materials and construction.
Carbon
- Guidance
Center of Expertise for Energy Efficiency in Data Centers
Lawrence Berkeley National Laboratory
Tools, guides and studies on data centre energy and water use from the US national laboratory that tracks it.
ComputeEnergyWater
- Guidance
Combined Heat and Power Partnership
US EPA
Screening tools and policy for on-site heat and power.
Energy
- Guidance
Commercial PACE
PACENation
Financing for building upgrades repaid through the property tax bill, so it stays with the building when it is sold.
EnergyWater
- Guidance
Renewable Energy Certificates
US EPA
What a certificate is. If you sell it, you no longer use renewable power in the eyes of the rules.
Energy
- Guidance
Water Reuse
US EPA
State reuse regulations and the national action plan.
Water
- Data
Annual Technology Baseline
National Laboratory of the Rockies (formerly NREL)
Cost and performance assumptions for generation technologies, current and projected.
Energy
- Data
Building Performance Standards
Institute for Market Transformation
Which US cities and states have a performance standard, and what each requires.
CarbonEnergy
- Data
Commercial Buildings Energy Consumption Survey
US Energy Information Administration
Energy use by building type, size, age and end use. The baseline to compare a building against.
Energy
- Data
Database of State Incentives for Renewables and Efficiency
NC Clean Energy Technology Center
Every US state and utility incentive, by location and technology.
Energy
- Data
eGRID
US EPA
Emission rates of US grid regions. Turns kilowatt-hours saved into tonnes.
EnergyCarbon
- Data
Epoch AI
Epoch AI
Open datasets on chips, models and data centres, with trends in compute over time.
Compute
- Data
GHG Emission Factors Hub
US EPA
Default factors for fuels, electricity and transport. The numbers behind most first-pass inventories.
CarbonEnergy
- Data
Green500
TOP500
The same machines ranked by work done per watt.
ComputeEnergy
- Data
GRESB Real Estate Assessment
GRESB
The benchmark property investors use to compare portfolios. Explains what an owner is asked to report.
CarbonEnergyWater
- Data
TOP500
TOP500
The ranked list of the largest computers, on one benchmark, twice a year since 1993.
Compute
- Data
Uptime Institute
Uptime Institute
Yearly surveys of data centre operators: efficiency, outages and capacity.
ComputeEnergy
- Data
Water security disclosure
CDP
What large companies report on water and what their customers ask of suppliers.
Water
- Data
Water Use in the United States
US Geological Survey
Withdrawals by county and by use: irrigation, industrial, thermoelectric, public supply.
Water
- Tool
Aqueduct Water Risk Atlas
World Resources Institute
Water stress by basin. A litre saved is worth more where the map is red.
Water
- Tool
Carbon Risk Real Estate Monitor
CRREM
Decarbonisation pathways by country and building type. Shows the year a building falls behind its pathway.
CarbonEnergy
- Tool
Embodied Carbon in Construction Calculator (EC3)
Building Transparency
Free database of product declarations. Shows where a material sits against its category.
Carbon
- Tool
ENERGY STAR Portfolio Manager
US EPA
Free benchmarking of a building's energy, water and emissions against its peers. Most US benchmarking laws report through it.
EnergyWaterCarbon
- Tool
PVWatts Calculator
National Laboratory of the Rockies (formerly NREL)
First estimate of solar output at an address.
Energy
- Report
AI Index Report
Stanford HAI
Yearly figures on the cost of training and running models, hardware and investment.
Compute
- Report
Buildings
International Energy Agency
World energy use and emissions from buildings, and how far each technology has got.
EnergyCarbon
- Report
Energy and AI
International Energy Agency
Data centres used about 1.5% of the world's electricity in 2024, and the report expects that to more than double by 2030.
EnergyCompute
- Report
Levelized Cost of Energy+
Lazard
Annual cost comparison of generation and storage technologies.
Energy
- Report
Rethinking Load Growth
Nicholas Institute, Duke University
How much new load the US grid could take if large users cut back for a few hours a year. The case for flexible data centres.
ComputeEnergy
- Report
Sixth Assessment Report: Mitigation of Climate Change
IPCC
Emissions by sector and the cost and potential of each mitigation option.
Carbon
- Report
Sixth Assessment Report: Mitigation, chapter 9, Buildings
IPCC
Direct, purchased and embodied emissions of buildings, and the cost of cutting each.
CarbonEnergy
Nothing matches. Try fewer filters.